List the appliances you want to run at the same time with their running and starting watts. Motors need extra power for a moment when they start.
Quick answer: Running = sum of running watts. For example, with safety margin of 20%, the recommended generator size is 4.38 kW.
Motors — fridges, pumps, compressors — draw two to three times their running power for a moment when they start. A generator must cover the total running load plus the largest starting surge. In the example, 2,450 W of running load with a sump pump starting at 2,000 W needs about 4.4 kW with a 20% margin.
For battery-based backup instead, see the Inverter Size Calculator.
| Appliances | A list — add or remove items as needed. |
|---|---|
| Safety margin | A percentage. |
Using the calculator’s example values (shown in US dollars and metric units — the calculator itself adapts to your country):
| Appliances | 5 × Appliance |
|---|---|
| Safety margin | 20% |
| Recommended generator size | 4.38 kW |
|---|---|
| Total running watts | 2,450 W |
| Peak watts (largest start) | 3,650 W |
| Approximate kVA (0.8 power factor) | 5.48 kVA |
We re-ran the example with each input 10% higher to see which ones move the recommended generator size most:
Focus on the first of these when you want to change the result. The calculator shows the biggest lever for your own numbers under the result.
Estimates only. Actual consumption depends on the appliance, settings, climate and your tariff structure.
Motors (fridges, pumps, AC compressors) briefly need two to three times their running power to start.
kW is real power. Generators are often rated in kVA; at a 0.8 power factor, kW ≈ kVA × 0.8.
Continuous operation near maximum shortens life. Keep typical load at 50–80% of the rating.
kVA is apparent power; kW is real power. With a typical power factor of 0.8, a 5 kVA generator supplies about 4 kW.
Running = sum of running watts. Peak = running + the largest single starting surge. Recommended = peak × (1 + margin).
You need appliances and safety margin. Example values are pre-filled, and the calculator converts between metric and imperial units and any currency.
If safety margin is 10% higher, the recommended generator size rises by 1.7% to 4.45 kW.