List the appliances you want to run during a power cut. The calculator totals the load, converts to VA and adds headroom to suggest a standard inverter size.
Quick answer: Load (W) = Σ watts × quantity. For example, with power factor of 0.8 and headroom of 25%, the suggested inverter size is 800 VA.
Add the watts of everything you want to run during an outage, divide by the power factor (about 0.8) and add headroom. Three fans, six LED lights, a TV, a router and a laptop come to 460 W — about 720 VA with 25% headroom, so an 800 VA inverter fits.
Inverters are rated in VA, appliances in watts: a 1,000 VA inverter supplies about 800 W.
Choose battery capacity for the backup time with the Battery Backup Calculator.
| Appliances | A list — add or remove items as needed. |
|---|---|
| Power factor | A number. |
| Headroom | A percentage. |
Using the calculator’s example values (shown in US dollars and metric units — the calculator itself adapts to your country):
| Appliances | 5 × Appliance |
|---|---|
| Power factor | 0.8 |
| Headroom | 25% |
| Suggested inverter size | 800 VA |
|---|---|
| Minimum VA with headroom | 719 VA |
| Total load | 460 W |
Estimates only. Actual consumption depends on the appliance, settings, climate and your tariff structure.
Add up the watts of what you want to run, divide by 0.8 and add about 25% headroom.
VA is apparent power; watts is real power. For typical home loads, W ≈ VA × 0.8.
No — backup time depends on the battery. Use the battery backup calculator for that.
A pure sine wave inverter of about 1,000 VA or more can usually run a home fridge; check the fridge’s starting current.
Load (W) = Σ watts × quantity. VA = load ÷ power factor × (1 + headroom). Suggested = next standard size up.
You need appliances, power factor and headroom. Example values are pre-filled, and the calculator converts between metric and imperial units and any currency.